Battery identifiers and QR codes
Every battery gets its own passport, reached by scanning a QR code on the battery or its packaging. Elara uses open standards for this, so your printed codes keep working even if you change provider.
The identifier
Each battery is identified by:
- GTIN: your product number from your company's own GS1 membership. GS1 is an issuing agency under ISO/IEC 15459, which the Battery Regulation requires (Art. 77(3)). If you aren't a GS1 member yet, you'll need to join (or use another ISO/IEC 15459 issuing agency).
- Serial number: 1 to 20 characters from the GS1 character set, no spaces (GS1 application identifier 21).
A GTIN can belong to only one SOCIII workspace.
The link in the QR code
Elara uses GS1 Digital Link (also published as ISO/IEC 18975):
https://{your id host}/01/{GTIN-14}/21/{serial} one battery
https://{your id host}/01/{GTIN-14} the battery model
Your own web address. The host is meant to be your brand's own subdomain (for example id.yourbrand.eu), pointed at SOCIII. If you ever change provider, you change one DNS record and every code you've already printed keeps working. That's the regulation's "no vendor lock-in" requirement. Setting up your own host is currently done with the SOCIII team; until it's set, codes use sociii.ai, which is only for demos and pilots, and Elara warns you before you print.
The QR symbol and label
- QR code (ISO/IEC 18004), error correction level Q, 4-module quiet zone.
- The human-readable identifier
(01)GTIN (21)serialis printed under it. - Elara generates the code from the identifier issued by SOCIII's server, never from free text, so a code can't point somewhere else.
- Labels print from the Batteries tab (SVG, 60 × 72 mm).
What a scan shows
Anyone who scans the code sees a phone-friendly public page with the public passport information for that battery and its manufacturer.
- Restricted information (for repairers, recyclers and authorities) needs sign-in. Those views open once the EU's rules on who may see what are final.
- Unknown, recycled and withheld codes all get the same neutral "No passport for this code" answer, so a scan reveals nothing it shouldn't.
- Identifiers are public by law. Security never depends on keeping them secret. If you don't want to reveal production volumes, use non-sequential serial numbers.
A battery's history
Each battery's record is built from events: manufactured, placed on the market, repaired, repurposed, remanufactured, recycled. Events are added, never edited, so the passport shows a complete history. When a battery is recycled, its public passport closes, as the regulation requires; the record is kept for the retention period.